Back to top
Horizontal Sidewall
Horizontal Sidewall

Horizontal Sidewall

MOQ : 5 Units

Horizontal Sidewall Specification

  • Installation Type
  • Wall-mounted, horizontal sidewall installation
  • Shape
  • Rectangular deflector with cylindrical body
  • Operating Pressure
  • Up to 12 Bar
  • Fire Class
  • Class A, B, C
  • Connectivity Type
  • Direct piping
  • Mounting Type
  • Wall-mounted
  • Fire Extinguisher Type
  • N/A (component for sprinkler system)
  • Coating Type
  • Chrome plated or brass finish
  • Voltage
  • Not applicable (mechanical device)
  • Coverage Area
  • Up to 4 x 6 meters
  • Technology
  • Glass bulb sprinkler technology
  • Working Temperature
  • 68C (standard), custom ratings available
  • Features
  • Quick response, corrosion-resistant, horizontal sidewall spray
  • Control Type
  • Automatic
  • Application
  • Fire suppression in commercial and residential buildings
  • Max Flow Rate
  • Up to 80 L/min
  • Diameter
  • 1/2 inch (15 mm)
  • Pressure
  • Minimum 1.2 Bar, Maximum 12 Bar
  • Maintenance
  • Annual inspection recommended
  • Thread Type
  • 1/2" BSPT or NPT
  • Response Time
  • Standard response 5mm bulb or quick response 3mm bulb
  • Deflector Type
  • Horizontal sidewall
  • Weight
  • Approx. 60 grams
  • K-Factor
  • 5.6 (80) US (metric)
  • Material
  • Brass, stainless steel spring
  • Spray Pattern
  • 180 sidewall discharge
  • Bulb Color
  • Red (standard 68C)
 

Horizontal Sidewall Trade Information

  • Minimum Order Quantity
  • 5 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Horizontal Sidewall



Experience supreme fire protection with our Horizontal Sidewall Sprinkler! Delivering dazzling performance, this value-driven solution features instant checkout and is easy to grab for quick installation. Designed for both commercial and residential spaces, it utilizes transcendent glass bulb technology, supporting either a standard 5mm or rapid 3mm bulb, with a remarkable K-Factor of 5.6. Chrome-plated brass ensures corrosion resistance, while the horizontal 180-degree sidewall spray maximizes coverage. Reliable and robust, this automatic sprinkler meets demanding fire safety needs while remaining low on maintenance and high on performance.

Versatile Application Across Sites

The Horizontal Sidewall Sprinkler is expertly crafted for use in diverse environments, ranging from commercial buildings to residential properties. Its transcendent 180-degree spray pattern makes it ideal for wall-mounted installations, particularly in corridors, hotels, malls, and offices. The device is tailored for automatic, direct piping connectivity, ensuring efficient fire suppression where it matters most. With a rectangular deflector and robust construction, it addresses the supreme safety needs of modern infrastructure, delivering dependable protection at every instant.


Export Markets, Sample Policy, and Freight Details

Our Horizontal Sidewall Sprinklers are exported to leading markets worldwide. Interested buyers may request a product sample under our transparent sample policy. List price and customized quotation are available upon inquiry, including detailed freight options from our main Indian FOB port. We prioritize cost-effective shipping and offer quotations with all charges detailed, helping you manage costs efficiently. Whether purchasing in bulk or sampling, our service ensures seamless acquisition to meet your project demands.


FAQ's of Horizontal Sidewall:


Q: How does the Horizontal Sidewall Sprinkler operate in a fire emergency?

A: The Horizontal Sidewall Sprinkler activates automatically when the ambient temperature reaches 68C, causing the red glass bulb to burst and release water in a 180-degree sidewall spray to quickly suppress the fire.

Q: What are the recommended application areas for this sprinkler model?

A: This sprinkler is best suited for commercial and residential settings such as offices, malls, hotels, corridors, and apartments, where wall-mounted fire suppression is required for optimal coverage.

Q: When should the Horizontal Sidewall Sprinkler be inspected?

A: An annual inspection is recommended to ensure the sprinkler maintains peak performance and complies with safety standards.

Q: Where can the Horizontal Sidewall Sprinkler be installed?

A: The device is designed for wall-mounted, horizontal sidewall installation, directly connected to the building's piping system, suitable for both new projects and retrofit applications.

Q: What is the process for purchasing this product from India as a supplier or trader?

A: To purchase, request a quotation including the list price and freight charges from our listed FOB port. Samples are available upon inquiry, ensuring you can evaluate the product before making a bulk order.

Q: What are the key benefits of using this particular sidewall sprinkler?

A: Benefits include quick response time, corrosion resistance, reliable horizontal spray coverage, and easy maintenance, ensuring transcendent fire protection and long-term value.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Extinguishers Category

Hood System Extinguishers

Hood System Extinguishers

Price 3200 INR / Unit

Minimum Order Quantity : 5 Units

Pressure : 14 bar (typical operating pressure)

Features : Quick suppression, nonconductive, low residue, corrosionresistant

Control Type : Manual and automatic discharge

Working Temperature : 10C to 55C

Chemical Powder Fire Extinguisher

Chemical Powder Fire Extinguisher

Price 2000 INR / Unit

Minimum Order Quantity : 5 Units

Pressure : 1215 bar

Features : Nonconductive, easytouse, efficient for various fire types, weatherresistant

Control Type : Manual trigger lever operated

Working Temperature : 20C to +55C

Fire Extinguishers

Fire Extinguishers

Price 2100 INR / Unit

Minimum Order Quantity : 5 Units

Pressure : Typically 1215 bar for standard extinguishers

Features : Portable, WallMountable, High Visibility, EasytoUse

Control Type : Manual Operation

Working Temperature : Typically 30C to +60C

Hose Reel

Hose Reel

Minimum Order Quantity : 5 Units

Pressure : Max 12 Bar

Features : Corrosion Resistant, Easy Rewind, Wall Mounted

Control Type : Hand Operated Valve

Working Temperature : Up to 60C